Finden Sie schnell lan kabel cat 8 für Ihr Unternehmen: 193 Ergebnisse

RE-2Y(St)YQY-fl MP

RE-2Y(St)YQY-fl MP

INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, STEEL WIRE BRAIDED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the sheath, steel wire braid serves as protection against mechanical traverse loads and act as a magnetic screen against interference. The galvanised steel wires are free of corresion and oxidation.These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: PE compound, EN 50290-2-23 Core identification: Black / White cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: PVC compound, EN 50290-2-22 Armour: Braid of galvanized steel wires, aprx. %85 cov. Outer sheath: PVC comp., flame retardant; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range: operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm
BayEnergy®  N2XH-O  0,6/1 kV  3 ¹/₂

BayEnergy® N2XH-O 0,6/1 kV 3 ¹/₂

Starkstromkabel mit verbessertem Verhalten im Brandfall, halogenfrei, flammwidrig und raucharm z.B. für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen. Kabel mit verbessertem Verhalten im Brandfall. Im Innen- und Außenbereich, im Freien (vor Sonneneinstrahlung geschützt), jedoch nicht direkt in der Erde, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist, (siehe DIN VDE 0298-1).
Kabel mit cUL-Zulassung für die Robotik

Kabel mit cUL-Zulassung für die Robotik

Je nach Einsatzbereich und Funktion eines Roboters, muss die Verkabelung unterschiedlichste Anforderungen erfüllen. So müssen Kabel und Leitungen für Industrieroboter in der Regel starken mechanischen Beanspruchungen durch permanent gleiche Bewegungsabläufe standhalten. Bei Robotern für beispielsweise Schweiß- oder Unterwasserarbeiten sind zusätzliche Eigenschaften wie Hitzeresistenz oder absolute Wasserdichtheit gefordert. Je nachdem, wie viele Funktionalitäten ein Roboter haben soll, fällt auch der Leitungsumfang aus. So individuell, wie die Anforderungen hier sind, gibt es keine Lösungen von der Stange. Für die Robotik müssen Kabel und Leitungen grundsätzlich individuell, anwendungsbezogen und bedarfsgerecht konzipiert und entwickelt werden. Daher ermitteln unsere erfahrenen Experten vor der eigentlichen Realisierung gemeinsam mit Ihnen alle Anforderungen, Einsatzbedingungen und gegebenenfalls Sonderwünsche.
BayEnergy® NA2XCWY  0,6/1 kV  4+1-adrig

BayEnergy® NA2XCWY 0,6/1 kV 4+1-adrig

Starkstromkabel für höhere Leitertemperaturen zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. In Innenräumen und Kabelkanälen, im Freien, im Erdreich für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, wenn ein Schutz gegen Berührungsspannung bei mechanischer Beschädigung erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die EMV+ Konstruktion wird speziell im 4+1 Leitersystem TN-S mit einem getrennten Neutralleiter (N) und querschnittsgleichem Schutzleiter (PE) eingesetzt. Durch den besseren Leitwert im PE-Leiter werden EMV-Störungen optimal reduziert und bieten einen höheren Schutz als bei Kabeln mit reduziertem Außenleiter (4½-Leiter). Die Kabel sind unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen.
BayEnergy®  NAYY-O  0,6/1 kV  4-adrig

BayEnergy® NAYY-O 0,6/1 kV 4-adrig

Starkstromkabel für Kraftwerke, Industrie- und Schaltanlagen, sowie Ortsnetze, falls kein erhöhter mechanischer Schutz erforderlich ist (siehe DIN VDE 0298-1). In Innenräumen und Kabelkanälen, im Freien, im Erdreich für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist. (Siehe DIN VDE 0298-1). Die Kabel sind UV-beständig und unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen.
RE-2G(St)H-CI  FE180 MP

RE-2G(St)H-CI FE180 MP

HALOGEN-FREE FIRE RESISTANT (CI) INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-PAIR, SILICONE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used on the basis of a fixed operating mode, can continue with the supply of a power under the existing fire conditions and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: Special silicone rubber compound Core identification: Black / Blue cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath: HFFR compound, EN 50290-2-27 L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Standard: TS/DIN EN 50288-7, (Designed according to) Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m Rated voltage: 500V Test voltage: Urms core-core : 2000 V, Urms core-screen : 2000 V Temperature range: operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Circuit integrity (CI): IEC 60331 , VDE 0472-814, BS 6387 Cat. CWZ Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2
BayEnergy®  N2XH-J  0,6/1 kV  4-5-adrig

BayEnergy® N2XH-J 0,6/1 kV 4-5-adrig

Starkstromkabel mit verbessertem Verhalten im Brandfall, halogenfrei, flammwidrig und raucharm z.B. für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen. Kabel mit verbessertem Verhalten im Brandfall. Im Innen- und Außenbereich, im Freien (vor Sonneneinstrahlung geschützt), jedoch nicht direkt in der Erde, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist, (siehe DIN VDE 0298-1).
BayEnergy® N2XY-O  0,6/1 kV  4-5-adrig

BayEnergy® N2XY-O 0,6/1 kV 4-5-adrig

Starkstromkabel für höhere Leitertemperaturen, insbesondere für Kraftwerke, Industrie- und Schaltanlagen, sowie Ortsnetze, falls kein erhöhter mechanischer Schutz erforderlich ist. Im Innen- und Außenbereich, im Freien, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen.
BayMotion®  Flex Power+  0,6/1 kV  1-adrig

BayMotion® Flex Power+ 0,6/1 kV 1-adrig

Hochflexible, halogenfreie, flammwidrige, UV- und witterungsbeständige, erdverlegbare Anschlussleitung mit einer sehr temperaturbeständigen Leiterisolierung aus einer speziellen HP Elastomermischung. BayMotion® CPR Eca Flex Power + ist eine hochflexible, halogenfreie, flammwidrige, UV- und witterungsbeständige, erdverlegbare Anschlussleitung mit einer sehr temperaturbeständigen Leiterisolierung aus einer speziellen HP Elastomermischung für den Einsatz im Anlagen- und Maschinenbau. Die Leitung ist ölbeständig und garantiert eine lange Lebensdauer in belasteter Umgebung, z. B. bei Anschlüssen von Transformatoren." Universell einsetzbar, zur festen Verlegung in trockenen und feuchten Räumen, im Freien und direkt in Erde Einfache Montage durch hochflexible Ader Temperaturbeständige Leiterisolierung für erhöhte Strombelastbarkeit Optional auch für 1,8/3 kV erhältlich *) im Dreieck mit Berührung angeordnet. Die Anforderungen der Strombelastbarkeit nach VDE 0276-603 Teil 5G beachten.
BayEnergy®  N2XCH 0,6/1 kV vieladrig

BayEnergy® N2XCH 0,6/1 kV vieladrig

Starkstromkabel mit verbessertem Verhalten im Brandfall, halogenfrei, flammwidrig und raucharm z.B. für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen. Kabel mit verbessertem Verhalten im Brandfall. Im Innen- und Außenbereich, im Freien (vor Sonneneinstrahlung geschützt), jedoch nicht direkt in der Erde, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, wenn ein Schutz gegen Berührungsspannung bei mechanischer Beschädigung erforderlich ist. (Siehe DIN VDE 0298-1).
BayEnergy® N2XC2Y  0,6/1 kV  4 ¹/₂  &  4+1-adrig

BayEnergy® N2XC2Y 0,6/1 kV 4 ¹/₂ & 4+1-adrig

Starkstromkabel für höhere Leitertemperaturen mit widerstandsfähigem HDPE-Außenmantel zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Außenbereich, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, wenn ein Schutz gegen Berührungsspannung bei mechanischer Beschädigung erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind halogenfrei, UV-beständig und durch den HDPE-Außenmantel besonders widerstandsfähig. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
RE-2Y(St)Y-fl-MP

RE-2Y(St)Y-fl-MP

INSTRUMENTATION CABLES, BS 5308 PART 1 TYPE 1SİNGLE & MULTİ-PAİR, PE INSULATED, COLLECTİVE SCREENED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. These cables are not recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , 0,50 mm2 and 1,0 mm2 solid,, 0,50 mm2 flexible or 1,5 mm2 stranded Insulation: PE compound, BS 6234 Type03 Core identification: According to BS 5308 Part 1 colour coded, *Upon request ; Black / White cores numbered 1-1, 2-2,… Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black Rated voltage: 300/500V Standard: BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m (≤2 pairs),max. 75 pF/m (all other pairs), 1,0 mm2 : max. 115 pF/m (≤2 pairs),max. 75 pF/m (all other pairs), 1,5 mm2 : max. 120 pF/m (≤2 pairs),max. 85 pF/m (all other pairs) Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω, 1,5mm2 : 40 µH/Ω Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
RE-2Y(St)YQY-fl

RE-2Y(St)YQY-fl

INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTIVE SCREENED, STEEL WIRE BRAIDED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the sheath, steel wire braid serves as protection against mechanical traverse loads and act as a magnetic screen against interference. The galvanised steel wires are free of corresion and oxidation.These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: PE compound, EN 50290-2-23 Core identification: Black / White / Red cores are numbered, (1-1-1, 2-2-2,…), Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: PVC compound, EN 50290-2-22 Armour: Braid of galvanized steel wires, aprx. %85 cov. Outer sheath: PVC comp., flame retardant; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range: operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1
RE-2YCYSWAY-fl-PIMF

RE-2YCYSWAY-fl-PIMF

INSTRUMENTATION CABLES, EN 50288-7MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: PE compound, EN 50290-2-23 Core identification: Black / White ; with numbered tape under , separator tape of the pair screen, Upon request ; Black / White cores numbered 1-1, 2-2,…, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, It can be manufacture as RE-2Y(St)CYSWAY-PIMF upon request. Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: Braid of tinned Cu wires, 85% coverage Inner sheath: PVC compound, EN 50290-2-22 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: PVC comp., flame retardant; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: max. 120 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range: operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1
BayEnergy® N2XCY 0,6/1 kV vieladrig

BayEnergy® N2XCY 0,6/1 kV vieladrig

Starkstromkabel für höhere Leitertemperaturen zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Innen- und Außenbereich, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, wenn ein Schutz gegen Berührungsspannung bei mechanischer Beschädigung erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind und unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen.
BayEnergy® N2X2Y-J  0,6/1 kV  4-5-adrig

BayEnergy® N2X2Y-J 0,6/1 kV 4-5-adrig

Starkstromkabel für höhere Leitertemperaturen mit widerstandsfähigem HDPE-Außenmantel zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Außenbereich, im Freien, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind halogenfrei, UV-beständig und durch den HDPE-Außenmantel besonders widerstandsfähig. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
RE-2Y(St)2YSWAY-fl-MP

RE-2Y(St)2YSWAY-fl-MP

INSTRUMENTATION CABLES, BS 5308 PART 1 TYPE 2SİNGLE & MULTİ-PAİR, PE INSULATED, COLLECTİVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , 0,50 mm2 and 1,0 mm2 solid,, 0,50 mm2 flexible or 1,5 mm2 stranded Insulation: PE compound, BS 6234 Type03 Core identification: According to BS 5308 Part 1 colour coded, *Upon request ; Black / White cores numbered 1-1-1, 2-2-2,… Pair: Two conductors twisted to a pair Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: PE compound, BS 6234 Type 03, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black Standard: BS 5308 Part 1 Type 2 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m (≤2 pairs),max. 75 pF/m (all other pairs), 1,0 mm2 : max. 115 pF/m (≤2 pairs),max. 75 pF/m (all other pairs), 1,5 mm2 : max. 120 pF/m (≤2 pairs),max. 85 pF/m (all other pairs) Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
BaySpecial®  NAEKEBY  18/30 kV  3-adrig

BaySpecial® NAEKEBY 18/30 kV 3-adrig

Massekabel/Dreibleimantelkabel für die Verlegung in Erde, im Freien, in Innenräumen und Kabelkanälen, wenn keine besonderen mechanischen Beanspruchungen zu erwarten sind (siehe DIN VDE 0298-1). In Erde, im Freien, in Innenräumen und Kabelkanälen, wenn keine besonderen mechanischen Beanspruchungen zu erwarten sind (siehe DIN VDE 0298-1). Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
BayEnergy®  NYFGY-J  0,6/1 kV  3 ¹/₂

BayEnergy® NYFGY-J 0,6/1 kV 3 ¹/₂

Starkstromkabel zur Energieverteilung im Bergbau unter Tage, in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Außenbereich, im Freien, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, wenn ein zusätzlicher Schutz gegen mechanische Beschädigung erforderlich ist und bei erhöhten Zugkräften während der Montage, Verlegung und des Betriebes. Die Kabel sind unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Aufgrund des flammwidrigen Mantels könnte es in die Brandklasse Eca eingestuft werden.
BaySpecial®  NAEKEBY  21/36 kV  3-adrig

BaySpecial® NAEKEBY 21/36 kV 3-adrig

Massekabel/Dreibleimantelkabel für die Verlegung in Erde, im Freien, in Innenräumen und Kabelkanälen, wenn keine besonderen mechanischen Beanspruchungen zu erwarten sind (siehe DIN VDE 0298-1). In Erde, im Freien, in Innenräumen und Kabelkanälen, wenn keine besonderen mechanischen Beanspruchungen zu erwarten sind (siehe DIN VDE 0298-1). Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
BayEnergy® N2X2Y-O  0,6/1 kV  4-5-adrig

BayEnergy® N2X2Y-O 0,6/1 kV 4-5-adrig

Starkstromkabel für höhere Leitertemperaturen mit widerstandsfähigem HDPE-Außenmantel zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Außenbereich, im Freien, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind halogenfrei, UV-beständig und durch den HDPE-Außenmantel besonders widerstandsfähig. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
RE-2Y(St)YQY-fl-PIMF

RE-2Y(St)YQY-fl-PIMF

INSTRUMENTATION CABLES, EN 50288-7MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, STEEL WIRE BRAIDED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the sheath, steel wire braid serves as protection against mechanical traverse loads and act as a magnetic screen against interference. The galvanised steel wires are free of corresion and oxidation.These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: PE compound, EN 50290-2-23 Core identification: Black / White ; with numbered tape under , separator tape of the pair screen, Upon request ; Black / White cores numbered 1-1, 2-2,…, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: PVC compound, EN 50290-2-22 Armour: Braid of galvanized steel wires, aprx. %85 cov. Outer sheath: PVC comp., flame retardant; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: max. 120 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range: operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1
Ladekabel 4 in 1 Glow - schwarz

Ladekabel 4 in 1 Glow - schwarz

Durch eine Gravur wird die darunter liegende LED sichtbar und bringt so Ihr Logo zum Strahlen. Die LED-Farbe ist weiß. Mit seinen 4 Anschlüssen (USB, Micro, Lightning und TYP-C) ist das Ladekabel für jedes Mobiltelefon geeignet. Inkl. kleinem stabilen Keyring Geliefert wird das Kabel in einem hochwertigen PVC-Bag mit bedruckter Trägerkarte. Das leuchtende Logo auf einer Position ist inklusive. Artikelnummer: 1344775 Breite: 25 Gewicht: 2g Höhe: 12 Kapazität: - Länge: 1150 Maße: 25 x 1150 x 12 mm
BayEnergy®  NA2X2Y-J  0,6/1 kV  4-adrig

BayEnergy® NA2X2Y-J 0,6/1 kV 4-adrig

Starkstromkabel für höhere Leitertemperaturen mit widerstandsfähigem HDPE-Außenmantel zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Freien und im Erdreich für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind halogenfrei, UV-beständig und durch den HDPE-Außenmantel besonders widerstandsfähig. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
RE-2Y(St)2YSWAY-fl-PIMF

RE-2Y(St)2YSWAY-fl-PIMF

INSTRUMENTATION CABLES, BS 5308 PART 1 TYPE 2MULTİ-PAİR, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Insulation: PE compound, BS 6234 Type03 Core identification: Black / blue ; with numbered tape under, separator tape of the pair screen, *Upon request ; Black / White cores numbered 1-1, 2-2,… Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over tinned copper drain wire, 0,50 mm2 Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: PE compound, BS 6234 Type 03, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black Conductor: Plain annealed copper wire, BS 6360 , 0,50 mm2 and 1,0 mm2 solid,, 0,50 mm2 flexible or 1,5 mm2 stranded Standard: BS 5308 Part 1 Type 2 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m, 1,0 mm2 : max. 115 pF/m, 1,5 mm2 : max. 120 pF/m Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
BaySpecial®  NAEKEBA  21/36 kV  3-adrig

BaySpecial® NAEKEBA 21/36 kV 3-adrig

Massekabel/Dreibleimantelkabel für die Verlegung im Freien und im Erdreich, insbesondere für Kraftwerke, Industrie- und Schaltanlagen, sowie Ortsnetze. Im Freien und im Erdreich für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
BaySpecial®  NAEKEBA  12/20 kV  3-adrig

BaySpecial® NAEKEBA 12/20 kV 3-adrig

Massekabel/Dreibleimantelkabel für die Verlegung im Freien und im Erdreich, insbesondere für Kraftwerke, Industrie- und Schaltanlagen, sowie Ortsnetze. Im Freien und im Erdreich für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
BayEnergy® NA2XY-J 0,6/1 kV 4-adrig

BayEnergy® NA2XY-J 0,6/1 kV 4-adrig

Starkstromkabel für höhere Leitertemperaturen, insbesondere für Kraftwerke, Industrie- und Schaltanlagen, sowie Ortsnetze, falls kein erhöhter mechanischer Schutz erforderlich ist. In Innenräumen und Kabelkanälen, im Freien, im Erdreich für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen.
BayEnergy® N2XCY 0,6/1 kV 4+1-adrig

BayEnergy® N2XCY 0,6/1 kV 4+1-adrig

Starkstromkabel für höhere Leitertemperaturen zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Innen- und Außenbereich, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, wenn ein Schutz gegen Berührungsspannung bei mechanischer Beschädigung erforderlich ist. (Siehe DIN VDE 0298-1). Die EMV+ Konstruktion wird speziell im 4+1 Leitersystem TN-S mit einem getrennten Neutralleiter (N) und querschnittsgleichem Schutzleiter (PE) eingesetzt. Durch den besseren Leitwert im PE-Leiter werden EMV-Störungen optimal reduziert und bieten einen höheren Schutz als bei Kabeln mit reduziertem Außenleiter (4½-Leiter). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur und eine höhere Belastbarkeit im Kurzschlussfall als vergleichbare Kabel mit PVC-Aderisolierung.
BaySpecial®  NAEKEBA  18/30 kV  3-adrig

BaySpecial® NAEKEBA 18/30 kV 3-adrig

Massekabel/Dreibleimantelkabel für die Verlegung im Freien und im Erdreich, insbesondere für Kraftwerke, Industrie- und Schaltanlagen, sowie Ortsnetze. Im Freien und im Erdreich für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.